5 Parameter Patient Monitor 12.1″

5 Multi-Parameter Patient Monitor 12.1″ Supplied by Ambulance Products India

Specs:-

Quality Standards and Classification
CE, IS013485
SFDA: Class II b
Anti-electroshock degree:
Class I equipment
(internal power supply)
TEMP/SpO 2 /NIBP: BF
ECG/Resp: CFApplication Range
Adult / Paediatric / Neonatal / Medicine / Surgery /
Operating Room / lCU / CCU
Display
12.1″ real color TFT screenEnvironment
Operating environment :
Temperature: 0 ~40 C
Humidity: 15%~80%
Pressure: 86.0 kPa~106.0kPa
Transport and Storage environment :
Temperature: -20 ~55 C
Humidity: 10%~90%
Pressure: 86.0 kPa~106.0kPa

Power Requirements
AC: 100 – 240V, 50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 11.1V 24wh Li-ion battery
2h operating after full charge
5min operating after low battery alarm

Dimension and Weight
Equipment:
340mm x 245mm x134 mm (about);
2.798kg (about)
Package:
380mm x350 mm x 300mm; 4.598 kg (about)Date Storage
Trend diagram/table: 7x24h
N I BP review: 400 events
Wave review: 100min
Alarm review: 100 alarm events
Support drug concentration titration analysisECG
5 Leads: RA, LA, LL, RL, V
Lead mode: I, II, III, AVR, AVL, AVF, V
Gain: x 1.25mm/mV,2.5mm/mV,
5.0mm/mV, 10mm/mV,
20mm/mV (error≥ 5%)
Sweep speed: 6.25mm/s,12.5mm/s,25mm/s,
50mm/s (error ≥ ± 10%)
Bandwidth: Surgery 1~25 Hz
Monitor 0.5 ~40 Hz
Diagnostic 0.05 ~130 Hz
Sensitivity: >200 µ V P-P
CMRR: ≥112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential: ±300mV
Polarization Voltage: ≥ ± 500mV
Input Impedance: ≥ 5 M
Calibration Voltage: 1 mV ± 5%

ST Segment
ST Segment Range: -2.0mV ~ +2.0mV
Accuracy: 0.02mVNIBP
Method: Oscillometry
Measure mode: Manual, Auto, STAT
Measure interval in auto mode:
1~5/10/15/30/60/90/120/180/240/480min
Measure period in STAT mode: 5min
Pulse rate range: 40 ~240bpm
Measure & alarm range: Adult
SYS 40~280mmHg
DIA 10~220mmHg
MEAN 20~240mmHg
Paediatric
SYS 40~220mmHg
DIA 10~160mmHg
MEAN 20~170mmHg
Neonatal
SYS 40~135mmHg
DIA 10~100mmHg
MEAN 20~110mmHg
Static pressure measurement
Range: 0 ~ 300mmHg
Accuracy: ± 3mmHg
Resolution: 1 mmHg Accuracy:
Max. Mean Error: ± 5mmHg
Max. Standard Deviation: 8mmHg
Overpressure protection:
Adult 300mmHg
Paediatric 240mmHg
Neonatal 150mmHg
Sp02
Measurement range: 0~100%
Resolution: 1%
Accuracy: 70%~100% ± 2%
40%~69% ± 3%Pulse Rate
Measure/alarm range: 20 ~300bpm
Resolution: 1 bpm
Accuracy: ± 3bpmRESP
Method: impedance between RA-LL
Resp Impedance range: 0.3 – 3 ?
Base Impedance range: 200 Q – 4000 ?
Bandwidth: 0.3~2.5Hz
Gain: x 0.25, x 0.5, x 1, x 2, x 4
Resp rate:
Measurement Range
Adult 0~120BrPM
Neonatal/Paediatric 0~150BrPM
Resolution: 1BrPM
Accuracy: 7~150BrPM (± 2BrPM)
0 – 6BrPM (unspecified)
Apnea Alarm: 10 ~40s

TEMP
Channel 2
Measure & alarm range: 0~50 °C
Resolution: 0.1 °C
Accuracy (no sensor): ±0.1 C (0~50 °C)

Standard accessories
• NIBP cuff & tube
• ECG cable & electrodes
• SpO2 sensor
• TEMP probe
• Lithium-ion battery
• Power cable
• Operator’s manual
We are Exporters and Suppliers of 5 Multi-Parameter Patient Monitor 12.1″ at competitive prices from India.

For More Information, visit us at www.descomedicalindia.com

Model No 
IEPM 110        5 Parameter Patient Monitor 12.1″

Reviews

There are no reviews yet.

Be the first to review “5 Parameter Patient Monitor 12.1″”

Your email address will not be published. Required fields are marked *